Operation N8200 & N8200-ST
N8200 and N8200-ST Series frost tops are designed to maintain
an even layer of frost to pleasantly display product. Once turned
on, the compressor will run continuously. The unit should be
turned off overnight or when not in use. There is no temperature
control. The ON/OFF switch is the only means available to cycle
the unit.
Since it takes time for the frost to accumulate initially, the unit
should be turned on approximately one hour before it is actually
required. Product should not be placed on the frost top prior to
turning the unit on, because it may freeze to the surface of the
unit.
The unit must be turned off when not in use or overnight for
defrosting and cleaning.
Operation N8200G
N8200G Series granite cold slabs are designed to maintain a
low temperature surface for quick turn products such as ice
cream. Frost patterns will vary depending on room conditions
such as temperature, humidity and airow. The “work zone”
of the granite surface is considered to be inside a 2” (5.1cm)
perimeter. Temperatures in the perimeter zone may be higher
and again the frost patterns in this area will vary based on room
conditions.
Unit is controlled by an on/off switch. Once turned on, the unit
will run continuously. There is no temperature control in this unit.
Turn the unit on approximately two hours prior to use to allow
for ample cool down time. The unit must be turned off when not
in use or overnight for defrosting and cleaning.
There is a switch on the compressor housing front to turn the
8100-EF units on and off. 8100-EF Series LiquiTec
®
Eutetic
uid cold pans are adjusted at the factory to provide proper
operation without any further adjustments. However, if it is
necessary to adjust the temperature, the control is located in
the machine compartment. Turn the knob clockwise as indicated
on the control to adjust it colder. Adjustments should be made
gradually. Several small adjustments will be more effective than
one large adjustment. It may take an hour or longer to realize
the temperature change depending on the application and
location of the unit.
The cold pan is not intended to be used with
ice.
Operation 8100-EF Series
The unit must be turned off when not in use or overnight for
defrosting and cleaning.
Temperature Control Settings:
17°F (8ºC) differential
25°F (-4ºC) cut-in
8°F (-13ºC)cut-out