N8000 Series Drop-In Installation and Operation Manual
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
12
These units are intended for indoor use only. Be sure the location
chosen has a counter strong enough to support the total weight
of the unit and contents. A fully loaded model may weigh as
much as 600 pounds! Reinforce the counter as necessary to
provide maximum loading.
Unit requires that the sides and bottom are not
any closer than 3” (7.6cm) to any combustible
material.
The counter cut-out sizes and power requirements are shown
on the specication pages. A gasket is installed in the ange
of each unit. The weight of the unit on the gasket forms a seal
preventing liquids from seeping into the cut-out opening.
N8700 Series pans should be installed with the
drains at the back, away from the operators
sides.
The controls on N8700-D, N8700-DESP, N8700-R and N8800
series units are mounted in a control panel, designed to be
installed at a “remote location. The control panel should be
installed so that the indicator light for each control is to the
right of the control. N8700, N8700N and N8700-R series units
have 48” (121.9cm) of conduit and N8800 Series units have 24”
(61.0cm) of conduit between the pans and the remote control
panel to facilitate this installation.
Plumbing
N8700-D, N8700-DESP, N8700N-D and N8700-R Plumbing:
Unit is equipped with 1/2” (1.3cm) drains, (one per well located
in right rear corner 1/2” (1.3cm) female N.P.T.) manifold and 1/2”
(1.3cm) gate valve.
N8800 Plumbing: Well is sloped to a 1.00” (2.5cm) male N.P.T.
stainless steel drain.
Moisture collecting from improper drainage
can create a slippery surface on the oor
and a hazard to employees. It is the owners
responsibility to provide a container or outlet
for drainage.
Electrical connection
Refer to the amperage data on the specication pages, the
serial tag or your local code to be sure the unit is connected to
the proper power source.
The unit must be disconnected from the
power source whenever performing service
or maintenance functions.
CAUTION
DANGER
Installation N8700-D, N8700-DESP, N8700N, N8700-R & N8800 Series
Control Panel Installation, N8700-D, N8700-DESP, N8700N & N8700-R Series
Drains
Control panel
installed
opposite drains
The control panel is designed to be installed on the side
opposite the drains.
If you choose to install the control panel on the same side as the
drains the control panel will either be upside down or the knobs
will control the opposite wells.
Infinite control shown, directions also apply to digital control